UNBONDED STRAND/PE STRAND

UNBONDED STRAND/PE STRAND

Low relaxation prestressed concrete stand size:9.3/9.53/12.7/12.9/15.24/15.7mm

Standards:ASTMA416/BS5837/EN10138/AS/NZS4672/GB,etc.

Standard of ASTM A416
GradeNominal Diameter (mm)Diameter Tolerance (mm)Nominal Area (mm²)Nominal Weight (KG/1000m)Min Breaking Strength (KN)Min Yield Strength (KN)Min Elongation at Max Load (%)Relaxation
Initial Load Of Mine Nominal Breaking Strength1000h Value No More Than
2500.3759.53±0.451.614058980.13.50%60%
70%
80%
1%
2.5%
4.5%
0.43811.1169.68548120.1108.1
0.512.792.9730160.1144.1
0.615.2139.351094240.2216.2
2700.3759.530.65
-0.15
54.84432102.392.10%
0.43811.1174.19582137.9124.10%
0.512.798.71775183.7165.30%
0.615.21401102260.7234.60%
AS/NZS 4672.1:2007
Type
mm
Nominal Diameter
MM
Tensile Strength
MPa
Unit Weigh
g/m
Min Elongation
500mm
Min breaking strength
KN
0.1%yield strength KN0.2%yield strength KN
Standard 7 wire9.5185043223.50%10283.686.6
12.71870774184151156
15.217501122250205212
15.218301122261214222
Compact 7
wire
15.218201295300255264
 1817001750380323334
BS589613-1980
TypeNominal Diameter
MM
Tensile Strength
MPa
Unit Weigh
g/m
Min yield strength
kN
Min breaking strength
kN
Min Elongation
L0>600m%
1000h Value
No more than
Standard 7 wire15.2
15.2
1670
1860
1090
1102
197
221
232
260
3.5(l≥500mm)s2.5%
Super 7 wire12.9
15.7
15.7
1860
1770
1860
785
1180
1180
186
265
279
Compact 7 Wire12.7
15.2
18.0
1860
1820
1700
890
1295
1750
209
300
380